Audi Q5: Battery, Charging with Battery Charger -VAS5906-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required

  • Battery Charger -VAS5906-

Procedure

- Place the Battery Charger -VAS5906- in the engine compartment or under the vehicle.

- Connect the Battery Charger -VAS5906- to the power supply.

The Battery Charger -VAS5906- is in idle, the display comes on when it is "ready to be used".

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  Caution

  • Turn off the ignition and all electrical equipment.
  • Remove the key.

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

The charging process starts after approximately two seconds.

LEDs show the Battery -A- charge level. When all the lamps are on, the Battery -A- is charged.

When the Battery -A- is completely charged, the Battery Charger -VAS5906- automatically switches to maintenance charging.

  Caution

Sparks can result if the charging terminals are removed too early. End the charging process by pressing the START/STOP button.

Battery -A- Charging, Ending

- Press the START/STOP-button.

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5906- from the power.

    READ NEXT:

     Solar Battery Maintainer -VAS6102A-

    Solar Battery Maintainer -VAS6102A- Device Description Solar Battery Maintainer -VAS6102A- The Solar Battery Maintainer -VAS6102A- supports the vehicle electrical system and prevents the Battery -A-

     Generator, Checking

    Perform Generator Test Vehicle Diagnostic Tester is attached. - Select the Diagnostic mode and start the diagnostics. - Select the tab Test Plan. - Select Select Individual Tests and

     Carbon Brushes, Checking, All Bosch Generators from 2001

    Procedure - Remove the voltage regulator: to 2007. Refer to → Chapter "Voltage Regulator, Bosch Generator from 2001, Removing and Installing", after 2007 → Chapter "Voltage Regulat

    SEE MORE:

     On Board Diagnostic System (OBD)

    Malfunction Indicator Lamp (MIL) The Malfunction Indicator Lamp (MIL) in the instrument cluster > fig. 8 is part of the On-Board Diagnostic (OBD II) system. The warning/indicator light illuminates when the ignition is switched on and goes out after the engine starts and the idle has stabilize

     Overview - Rear Bumper Cover

    Overview - Bumper Cover, Audi Q5   Caution If the vehicle has lane change assistance, the lane change assistance control module -J769-/-J770- must be recalibrated. Refer to → Electrical Equipment; Rep. Gr.96; Lane Change Assistance; Lane Change Assistance, Calibrating. 1

    © 2019-2024 Copyright www.audiq5.net