Audi Q5 Owners & Service Manuals

Audi Q5: Battery, Charging with Battery Charger -VAS5095A-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

Special tools and workshop equipment required

  • Battery Charger -VAS5095A-

  Caution

While charging, always set the battery type to 2.4 V/C (Volts/Cell)! This applies to all Batteries -A-.

  Note

The Battery -A- temperature must be at least 10 ºC.

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Procedure

- Turn off the ignition and all electrical consumers and remove the ignition key.

- Check the battery type setting on the battery type switch. Refer to → Chapter "Battery Charger -VAS5095A- Device Description". The battery type switch must be set to 2.4V/C (Volts/Cell).

- Connect the red charge terminal (+) to the positive terminal of the Battery -A-.

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Connect the black charge terminal (-) to the negative terminal of the Battery -A-/negative connector.

- Switch on the Battery Charger -VAS5095A-. Refer to → Chapter "Battery Charger -VAS5095A- Device Description".

Charge current displays. Refer to → Fig. " Battery Charger -VAS5095A- "-2- and -3- light up yellow. The Battery -A- is partially charged (approximately 90 %) when only the yellow LED -3- is on.

If the green LED. Refer to → Fig. " Battery Charger -VAS5095A- "-4- is also on, then the Battery Charger -VAS5095A- has switched to maintenance charging. The Battery -A- is charged.

- Switch off the Battery Charger -VAS5095A-. Refer to → Chapter "Battery Charger -VAS5095A- Device Description".

- Remove the charging clamps from the battery terminals.

Severely Discharged Battery, Charging with Battery Charger -VAS5095A-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

The Battery Charger -VAS5095A- automatically detects severely discharged Batteries -A- and starts the charging process conservatively with a low charge current. The charge current is automatically adjusted to the battery charge state.

  Note

  • For information in the chapter. Refer to → Chapter "Severely Discharged Batteries".
  • The battery voltage must be at least 0.6 V!
  • Severely discharged Batteries -A- in vehicles must be replaced prior to delivery. Pre-existing damage cannot be ruled out.

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Procedure

- Charge the Battery -A-. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5095A-".

    READ NEXT:

     Battery Charger -VAS5095A- Support Mode

    General Information The support mode provides the vehicle electrical system with voltage when the Battery -A- is removed or disconnected. For more information. Refer to the Battery Charger -VAS5095A

     Battery Charger -VAS5900-

      WARNING Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".   WARNING Do not check or charge a Battery -A

     Battery Charger -VAS5900- Service Charge

      WARNING Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".   Caution "Service charging" is not permitted

    SEE MORE:

     O-Ring Seals

    These rings seal off the connection points between individual components of the refrigerant circuit. Only O-rings that are resistant to refrigerant R134a and refrigerant oil must be installed. Make sure they are original replacement parts. O-ring seals: - Always use only once. - Make su

     Working on the battery

    Be especially careful when working on or near the battery. The battery is located in the luggage compartment under the floor. Before you check anything in the luggage compartment, read and heed all WARNINGS. Hybrid drive: you can find important information about the high voltage battery under. Alw

    © 2019-2024 Copyright www.audiq5.net