General Information

The support mode provides the vehicle electrical system with voltage when the Battery -A- is removed or disconnected.

For more information. Refer to the Battery Charger -VAS5095A- Operating Instructions.

The support mode is used for the following situations:

  • Vehicle electrical system support mode with the Battery -A- not installed
  • Maintaining the voltage when the battery is being replaced
  • Systems test without the Battery -A-

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

Special tools and workshop equipment required

  • Battery Charger -VAS5095A-

Procedure

  Caution

  • The polarity protection of the charger clamps is not active in the operation mode "charging severely discharged batteries/Support mode". Connect the charger clamps to the battery terminals correctly according to polarity!
  • It can result in sparks due to short circuit.
  • This constitutes an explosion risk.
  • Make sure the charging clamp connections are secure.

- Remove the Battery -A-. Refer to → Electrical Equipment; Rep. Gr.27; Battery; Battery, Removing and Installing.

  Caution

Whenever the Battery -A- is removed, be careful to prevent contact between the connected charge clamp on the positive terminal and the body ground. Likewise prevent contact between the battery terminals.

- Clamp the red charging clamp (+) to the vehicle positive battery terminal.

  Note

On vehicles with a Start/Stop function and an installed Battery Monitoring Control Module -J367-, the black charge terminal (-) must be connected to the body ground. The Start/Stop system will malfunction when it is connected to the Battery -A- negative terminal.

- Attach the black charging clamp (-) to the vehicle battery negative terminal.

- Check the setting for the support mode/standard operation switch. Refer to → Chapter "Battery Charger -VAS5095A- Device Description". It must be set to "support mode".

- Check correct polarity connection of charger clamps.

- Switch on the Battery Charger -VAS5095A-. Refer to → Chapter "Battery Charger -VAS5095A- Device Description".

The Battery Charger -VAS5095A- starts the support mode.

End the Battery Support Mode

- Switch off the Battery Charger -VAS5095A-. Refer to → Chapter "Battery Charger -VAS5095A- Device Description".

- Remove the charging clamps from the battery terminals.

- Disconnect the Battery Charger -VAS5095A- from the power.

Battery Charger -VAS5095A- Maintenance Charging

  WARNING

Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".

  WARNING

Do not check or charge a Battery -A- when the visual indicator has "no color or is bright yellow". Jump starting must not be used!

There is a risk of explosion during testing, charging or jump starting.

These Batteries -A- must be replaced.

In maintenance charging, the Battery Charger -VAS5095A- provides safe charging and preserves the charge of the Battery -A-.

Procedure

- Proceed as if charging the Battery -A-. Refer to → Chapter "Battery, Charging with Battery Charger -VAS5095A-".

If the Battery -A- is discharged by an electrical consumer during maintenance charging, the Battery Charger -VAS5095A- automatically supplies the appropriate charge.

Maintenance charging can be performed without time restrictions. The Battery -A- can be used constantly.

    READ NEXT:

     Battery Charger -VAS5900-

      WARNING Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".   WARNING Do not check or charge a Battery -A

     Battery Charger -VAS5900- Service Charge

      WARNING Risk of injury. Follow all warning messages and safety precautions. Refer to → Chapter "Warnings and Safety Precautions".   Caution "Service charging" is not permitted

     Battery Charger -VAS5900- Support Mode

    General Information The support mode provides the vehicle electrical system with voltage when the Battery -A- is removed or disconnected. For more information. Refer to the Battery Charger -VAS5900-

    SEE MORE:

     Spring Tensioning System -VAS6274-, Converting

    Special tools and workshop equipment required Spring Tensioning System -VAS6274- Spring Tensioning System - Audi Set -VAS6274/10- Spring Tensioning System - Q5 Set -VAS6274/11-   Note It must only be converted once. It is not necessary to convert back again. - Remove the tensioning

     On Board Diagnostic System (OBD)

    Malfunction Indicator Lamp (MIL) The Malfunction Indicator Lamp (MIL) in the instrument cluster > fig. 8 is part of the On-Board Diagnostic (OBD II) system. The warning/indicator light illuminates when the ignition is switched on and goes out after the engine starts and the idle has stabilize

    © 2019-2024 Copyright www.audiq5.net